• כלים לשירותך
  • כניסה לחשבון שלי
האיגוד הישראלי לרדיולוגיה
Israel Radiological Association
יו"ר האיגוד:
פרופ' אילן שלף

מנהל ועורך אתר:
ד"ר איליה וולוביק
Deep Learning Prostate MRI Segmentation Accuracy and Robustness: A Systematic Review

להלן תקציר המאמר. ניתן לקרוא את הטקסט המלא בקישור

 

Fassia MK, Balasubramanian A, Woo S, Vargas HA, Hricak H, Konukoglu E, Becker AS. Deep Learning Prostate MRI Segmentation Accuracy and Robustness: A Systematic Review. Radiol Artif Intell. 2024 Jul;6(4):e230138. doi: 10.1148/ryai.230138. PMID: 38568094; PMCID: PMC11294957.

 

Abstract

Purpose To investigate the accuracy and robustness of prostate segmentation using deep learning across various training data sizes, MRI vendors, prostate zones, and testing methods relative to fellowship-trained diagnostic radiologists. Materials and Methods In this systematic review, Embase, PubMed, Scopus, and Web of Science databases were queried for English-language articles using keywords and related terms for prostate MRI segmentation and deep learning algorithms dated to July 31, 2022. A total of 691 articles from the search query were collected and subsequently filtered to 48 on the basis of predefined inclusion and exclusion criteria. Multiple characteristics were extracted from selected studies, such as deep learning algorithm performance, MRI vendor, and training dataset features. The primary outcome was comparison of mean Dice similarity coefficient (DSC) for prostate segmentation for deep learning algorithms versus diagnostic radiologists. Results Forty-eight studies were included. Most published deep learning algorithms for whole prostate gland segmentation (39 of 42 [93%]) had a DSC at or above expert level (DSC ≥ 0.86). The mean DSC was 0.79 ± 0.06 (SD) for peripheral zone, 0.87 ± 0.05 for transition zone, and 0.90 ± 0.04 for whole prostate gland segmentation. For selected studies that used one major MRI vendor, the mean DSCs of each were as follows: General Electric (three of 48 studies), 0.92 ± 0.03; Philips (four of 48 studies), 0.92 ± 0.02; and Siemens (six of 48 studies), 0.91 ± 0.03. Conclusion Deep learning algorithms for prostate MRI segmentation demonstrated accuracy similar to that of expert radiologists despite varying parameters; therefore, future research should shift toward evaluating segmentation robustness and patient outcomes across diverse clinical settings.

ברוכים הבאים לאיגוד הישראלי לרדיולוגיה

חברי האיגוד מוזמנים להתעדכן בפעילות האיגוד, לעקוב אחר יומן האירועים, לשלם דמי חבר, ולקרוא מאמרים
כניסה לחברי האיגוד
הציבור מוזמן לקרוא מידע על פעילות האיגוד הישראלי לרדיולוגיה
איני חבר/ת האיגוד